Tenney 164-3

Sold

Description

AEC & M & E JV - M & E #S730054Cust # 11920 questions: 10/21/03 & 10/27/03 - cust email - What voltage requirements for the chamber? Our present ones are 240 V. What refrigerants does the chamber require? Our present chambers use: R-13 and R-500. Are any drawings or manuals available for this unit? Is it possible to have a spec page(s) faxed out to me? (Forwarded questions to Dominic at M & E) 10/29/03 - per vendor - We did not get any paperwork in with these ovens. I will see if I can locate anything in our catalog files. It is rated for 460 volt & the refrigerant used was R-13. Also there is something missing under the chamber which is part of the cooling system. I do not know these ovens extremely well but it appears that it is missing a pump to move the refrigerant. I am not positive of that and can take a photo if you want to send it to the customer. (10/30 - forwarded to cust) 10/31/03 - per email from cust - Sorry for the delay in getting back to you. We needed to get our electricians to go out to the site where we will place the environmental chamber and see if we have enough power to meet the chambers 460 V requirements. I will let you know the results as soon as I can.12/2/03 - CUST #19690 question: Can I request pictures of the refrigeration gauges to verify charges?12/18 - forwarded question to M & E2/24/04 - Cust # Questions = What is HP? Ampherage? Refrig. in it now? The information I was able to retrieve is as follows:Motor - 1/2 HP 208-230/460 volt 3-phase 60 cycle 208 volt at 2.1 amps 230 volt at 2 amps & 460 volt at 1 amp. Compressors - B/M - 200 3-phase serial# STL/81G-17773 model# 9RB1 0760-TDF. 60 cycle - 460 volt RLA - 15.4 & LRA - 82.0 50 cycle - 380/400 volt RLA - 15.4 & LRA 82.0Please see the attached photos where I point out where the motor and compressors are located. Let me know if they have any further questions. AS FOR REFRIGERANT DOMINIC DOESNT THINK SO. HE SAID IT LOOKS LIKE THERE IS PIPING DOWN THERE WHICH WAS CUT PRIOR TO REMOVAL. THERE ARE NO PUMPS.setharnoldaec: PICTURES IN AUTO SAVE FOLDER3/24/04 - email to Dominic at M & E -I just spoke w/the accounts payable person re: the Tenney - Check should be cut on Monday sent on Tuesday we should have it on Wednesday.3/29/04 - per email from Dominic - Sounds good. We should have the machine ready for shipment by Wednesday.

Specifications

ManufacturerTenney
Model164-3
ConditionUsed
Serial Number10.493
Stock Number2827
Machine id2827
Machine descriptionTENNEY ENGINEERING ENVIRONMENTAL CHAMBER WITH CONTROLS
Machine code04L
Equipped with1 - Used Tenney Engineering Environmental Chamber 64 cu. ft. last operated -165 deg. F to 320 deg. F. With Micro Tenn controls and Honeywell Model 452X1-B chart recorder. (2) fan cooled compressors/condensers. Chamber measures 48 in. x 48 in. x 48 in.. With (2) trays. Stainless steel internals. O.A.D. - 6.5' X 6.5' X 8' H. APPROX. 3000 LBS. It is believed (not confirmed) that the humidifier and circulation pump are missing. F.O.B. - OUR N. CA WAREHOUSE
StatusS